Benefits and Features of Vista L2-ER Colorimeter / Spectrophotometer

Audit-Ready Color and Haze/Turbidity QC for 21 CFR Part 11 Compliance

Vista L2-ER records each colour measurement together with associated metadata, including the operator, instrument serial number, applicable calibration or standardization information, and date and time, and maintains the results as protected electronic records in EasyMatch Essentials L2-ER.

The system provides technical controls, including role-based access, audit trails, electronic signatures, and traceable data export, that support customer compliance with FDA 21 CFR Part 11 and is designed for EU GMP Annex 11, and Japan's MHLW ERES environments.

Vista L2-ER is a transmission color spectrophotometer/colorimeter used to measure the color of translucent and transparent liquids, built for regulated industries including pharmaceuticals, petrochemicals, biotech, food, and chemical manufacturing.

  1. A Locked, Reproducible Audit Trail

    Vista L2-ER writes each result into a locked audit trail with an automatic date and time stamp, and can reproduce those records in human-readable and electronic form, whenever an inspector asks.
  2. Pass/Fail Judgments, Views Your Way

    Set up the data views each analyst wants to see, and let Vista L2-ER mark every reading pass or fail against your specifications as the measurement lands.
  3. Controlled Access and Locked E-Signatures

    Only authenticated users get in, and their role decides what they can do, while password management and locked electronic signatures bind each approval to a named person.
  1. Every Reading Fully Traceable

    Because the operator, instrument, calibration, and timestamp travel with every result, you can trace any number back to how and when it was produced, without pulling a separate log.
  2. System Validation Documentation, Included

    Vista L2-ER ships with a printable PDF Validation and Compliance Notebook included, with IQ, OQ, and PQ content to support your FDA 21 CFR Part 11 validation from day one, backed by HunterLab’s ISO/IEC 17025-accredited calibration.
  3. Records That Reach Your Enterprise Systems

    Records leave Vista L2-ER as PDF, CSV, or XLSX and move through its available ports into LIMS, SPC, and MES, so results reach your enterprise systems without anyone re-typing a number.
  1. Update Locally, or Push Across the Network

    Update Vista L2-ER by USB, online from the instrument, or remotely through EasyMatch Quality Central, which pushes update files over the network to every connected instrument.
  2. Flexible Pathlength Measurement and Small Sample Volumes

    Vista L2-ER delivers absolute colour from standard 10 to 50 millimeter cells and vials, automatically reporting pathlength and APHA in cells far smaller than others require. No costly, hard-to-clean specialty cells. It reads very small spectral differences on sample volumes as low as 0.4 mL, which matters when biopharma samples are expensive.
  3. Modern Smart User Interface with Touchscreen and Color Display

    Durable and Efficient: Facilitates accurate color analysis in minutes with an intuitive interface and robust industrial glass design suitable for demanding environments.
  1. PC Computing Power Built-in

    No Computer Required: Functions as a fully self-contained colour workstation with onboard computing power and storage, enough for millions of measurements. No external PC required for measurement, analysis, data storage, or reporting.
  2. Simultaneous Colour and Haze/Turbidity Measurement

    Faster Decisions and Simplified Workflows: Measures both transmission colour and haze/turbidity in one step, improving efficiency and reducing operator error while supporting better QC and QA outcomes.
  3. Wide Range of Colour Scales and Indices

    Flexible and Standards-Ready: Supports Pt-Co/Hazen/APHA, Gardner Colour, Haze %, Opalescence, Y Total Transmission, Saybolt, Absorbance, CIE Spectral Data, LOVIBOND®, AOCS, Pharmacopoeia and many more to meet global industry requirements.

ProductSpecifications

Measurement

Measurement Principle: Dual-beam spectrophotometer

Geometry: Tt/0º or Td/0º per ASTM 1164, CIE 15:2018

Measurement Pathlength: Up to 100 mm

Measurement Time: 2.5 seconds

Measurement Time with Haze: 5 seconds

Measurement Interval: MIN 3 seconds

Port Size/Measured Area: 11 mm (0.43 in) illuminated/9.8 mm (0.39 in) measured

Transmission Modes: Tt (TTRAN) and Td (RTRAN) and Haze

Technical

Flashes per Measurement: 4 flashes

Measurement Pathlength: Up to 100 mm

Illumination and Measurement Range: 400 nm - 710 nm

Spectral Resolution: < 3 nm

Effective Bandwidth: 10 nm equivalent triangular

Reporting Interval: 10 nm

Photometric Range: 0 to 150 %

Photometric Resolution: 0.003 % (0.01 % reported)

Standards Conformance

  • Colorimetric: CIE 15:2018, ASTM E1164, DIN 5033 Teil 7 and JIS Z 8722 Condition E, G
  • Haze: ASTM D1003

Light Source: Full spectrum, balanced LED array

LED Life: 5 years typical

Sphere Diameter: 76 mm (3 in)

Sphere Coating: Spectralon™

Spectrophotometer: 256-element diode array;
high resolution concave holographic grating

Performance

Colorimetric Repeatability: < 0.02 ∆E* on air

Spectral Repeatability: Standard deviation within 0.1 % T

Inter-instrument Agreement:

  • ∆E* < 0.15 (Avg) (Transmission Filter Set)
  • ∆E* < 0.25 (Max) (Transmission Filter Set)
  • ± 0.30% Measuring 10% Haze

User Interface

Data Views: EZ View, Colour Data Table, Colour Plot, Spectral Data, Spectral Plot

Other Features: Pass/Fail colour indication, time and date stamp, auto-naming, auto-saving, data backup

Indices and Metrics: APHA/PtCo/Hazen, ADMI, Saybolt, Gardner, ASTM D1500, Iodine, EBC, ASBC, ASBC Turbidity, Chinese Acid Wash, LOVIBOND® RYBN, AOCS RY, AOCS Cc 13d-55 Chlorophyll Concentration, FAC, YI E313 Yellowness, YI D1925, WI E313, CIE Y Transmission, US Pharmacopeia, Japanese Pharmacopeia, EU Pharmacopeia, Chinese Pharmacopeia EP, Opalescence, Haze, NTU, ICUMSA and OffHue

Colour Scales: CIE L*a*b*, Hunter Lab, CIE L*C*h, CIE Yxy, CIE XYZ

Colour Difference Scales: ΔL*a*b*, ΔLab, ΔL*C*h, ΔYxy, ΔXYZ

Colour Difference Indices: ∆E*, ∆E, ∆ECMC (l:c), CIE ∆E 2000

Data Storage: 32 GB (> 4 million data records)

Illuminants: D65, C, A, D50, D55, D75, F02, F07, F11, TL84, ULT30, ULT35

Observers: 2° and 10°

Languages: Supports multiple languages—with the option to add more as needed

Display: Touch screen, high resolution 1280x800

External PC Software: Compatible with EasyMatch Quality Central

FDA Title 21 CFR Part 11 Compliance:Electronic Records and Electronic Signatures

Designed for EU GMP Annex 11 and MHLW ERES: Electronic Records and Electronic Signatures

Communications I/O

USB Connections: Connectivity to keyboard, mouse, flash drive, barcode QR code scanner

Front Panel USB: 2.0 bidirectional, data export/import via thumb drive

Ethernet RJ45: Print directly to network printers, stream data to LIMS and SPC systems

Physical / Electrical

Dimensions:

Height: 177.8 mm (7.0 in.)

Width: 485.8 mm (19.125 in.)

Depth: 228.6 mm (9.0 in.)

Weight: 6.35 kg (14.0 lbs)

Transmission Compartment:

Height: 108.0 mm (4.25 in.)*

Width: 101.6 mm (4.0 in.)

Depth: 187.3 mm (7.375 in.) with cover on*

*Removable cover opens compartment on three sides (top, front, back) to accomodate large samples

Base to Measurement Port Distance: 63.5 mm (2.5 in.)

Power Requirements: 100 to 240 VAC, 47 to 63 Hz, 60 W

Operating Environment: 10 to 40° C (50 to 104º F), 10 % to 90 % RH, noncondensing

Storage Environment: -21 to 66° C (-5 to 150º F), 10 % to 90 % RH, noncondensing

Standard Accessories:

  • Certificate of compliance
  • Validation Notebook for Vista L2-ER
  • Vista L2-ER Quick Start Guide
  • Stylus
  • USB Flash Drive
  • Cleaning Cloth
  • Power supply

What's in the Box

All you need to get accurate colour measurement in minutes!

Essential Items

Accessories

Is Vista L2-ER 21 CFR Part 11 compliant?

Vista L2-ER provides the technical controls FDA 21 CFR Part 11 requires for closed systems: audit trails, electronic signature locking, role-based access, and password management, all on the EasyMatch Essentials L2-ER platform. Full compliance also depends on your system configuration, validation, procedures, training, record-retention policies, and intended use. HunterLab supplies the validated platform and documentation, and your team adds the procedural controls such as SOPs and identity verification.

To learn more, Download FDA 21 CFR Part 11 Compliance Table for EasyMatch® Essentials-ER and Vista L2

How does Vista L2-ER protect data integrity?

Every measurement is linked to the operator, instrument serial number, calibration reference, and date and time, then autosaved as a permanent electronic record. Vista L2-ER can generate accurate, complete copies of those records in human-readable and electronic form for inspection, and any record altered outside the software is detected.

Does Vista L2-ER support electronic records and electronic signatures?

Yes. It captures secure electronic records with automatic date and time stamping and locks electronic signatures to a named user, so approvals and sign-offs live inside the record rather than on paper.

Can Vista L2-ER integrate with LIMS, SPC, and MES?

Yes. Records export to PDF, CSV, or XLSX and transmit through available ports, and results integrate with enterprise systems including LIMS, SPC, and MES.

What do IQ, OQ, and PQ involve with Vista L2-ER?

Vista L2-ER ships with a Validation and Compliance Notebook of checklists and documentation for system validation. IQ confirms correct installation and configuration, OQ demonstrates the instrument operates within specification, and PQ verifies performance using your routine methods, samples, and standards.

What samples can Vista L2-ER measure?

Vista L2-ER is a transmission spectrophotometer built for translucent and transparent liquids, films, and gels. It reads colour and haze/turbidity together in a single measurement (ASTM D1003 Procedure B) at pathlengths up to 100 mm, using a stable LED source.

How are Vista L2-ER software updates managed?

Updates run from a USB flash drive, online directly from the instrument, or remotely through EasyMatch Quality Central, which pushes update files over the network to every connected instrument. Recent releases add advanced PDF reporting, remote display sharing, time-limited license support, enhanced audit-log syncing, and session management.

Which standards and regulations does Vista L2-ER support?

Vista L2-ER supports CIE L*a*b*, Hunter Lab, CIE L*C*h, CIE Yxy, CIE XYZ color scales, ASTM D1003 Procedure B for haze/turbidity, and FDA 21 CFR Part 11 compliance, and is designed for EU GMP Annex 11, and Japan's MHLW ERES environments for electronic records and data integrity. It provides the technical controls (audit trails, access controls, and electronic signatures) that support customer compliance; full compliance also depends on your validation, procedures, and use.

Is Vista L2-ER's calibration traceable for Good Manufacturing Practice (GMP) and United States Pharmacopeia (USP) <1058>, Analytical Instrument Qualification?

Yes. HunterLab provides calibration traceability to support use in GMP-regulated laboratories and analytical instrument qualification programs based on USP <1058>. Where applicable and within the accredited scope, calibration is performed by HunterLab's ISO/IEC 17025-accredited calibration laboratory.

Which regulated industries is Vista L2-ER built for?

Bio-pharma, petrochemical, biotech, chemical, and food manufacturers, along with other regulated industries that need traceable, audit-ready colour and haze/turbidity records on liquids.

Can Vista L2-ER be used as a stand-alone compliant system, or networked?

Both. It runs as a self-contained stand-alone instrument and scales across sites through EasyMatch Quality Central, with remote display sharing and HDMI output for collaborative review.

Does Vista L2-ER support EU GMP Annex 11 and MHLW ERES?

Yes. EasyMatch Essentials L2-ER provides technical controls that support EU GMP Annex 11 and Japan's MHLW ERES guidelines alongside FDA 21 CFR Part 11: role-based access, audit trails, locked electronic signatures, and traceable data export. One instrument therefore serves sites across US, EU, and Japanese jurisdictions without separate systems. Compliance itself depends on your validation, SOPs, and intended use.

Trusted By The Best All Over The World

  • Eastman logo
  • Fisher Scientific logo
  • Niagara logo
  • Unilever logo

Master Your Colour Quality with
Vista L2
-ER.

Schedule a Demo of the new Vista L2-ER

Schedule Demo