Agera L2 benchtop spectrophotometer

Benefits and Features of Agera L2 Spectrophotometer/Colorimeter

The Agera L2 builds on the proven Agera platform with new features that support plastics, textiles, safety materials, coatings, retroreflectives, paper, and packaging—with added strength for color-critical, complex, UltraDark and fluorescent samples.

It is powered by Essentials 2.0, the most intuitive color analysis interface on the market. It brings together true CIE-quality D65 daylight illumination, UltraDark mode for deep-color precision, and a rugged, spill-proof design to help you measure color as it's truly seen.

  1. Integrierte PC-Rechenleistung

    Fungiert als völlig eigenständige Farb-Workstation mit integrierter Rechenleistung und Speicher, ausreichend für Millionen von Messungen. Für Messung, Analyse, Datenspeicherung oder Berichterstellung ist kein externer PC erforderlich.
  2. Zweck: Entwickelt für geschäftskritische Industrien

    Das Agera L2 wurde als Reflektionsspektrophotometer/Kolorimeter mit 0°/45° Umfangsreflexion (0/45 c) in Referenzqualität entwickelt und liefert genaue, wiederholbare Farbmessungen, bei denen enge Toleranzen und visuelle Übereinstimmung unerlässlich sind.
  3. Vereinfachte Bedienererfahrung

    Die Essentials L2-Software bietet eine übersichtliche, berührungsoptimierte Benutzeroberfläche. Unterstützt schnelle Entscheidungen mit minimalem Schulungsaufwand und behält bei Bedarf erweiterte Funktionen bei.
Agera L2 display screen
  1. Echte D65-Tageslichtbeleuchtung

    Die zertifizierte CIE D65-Quellenbeleuchtung der Klasse „A“ liefert Messungen, die auf die menschliche Sichtweise von Ihnen und Ihrem Kunden abgestimmt sind. Bietet im Laufe der Zeit konsistente visuelle Genauigkeit und Zuverlässigkeit in allen Laboren, Linien und Standorten.
  2. Verbesserte Leistung für dunkle und optisch anspruchsvolle Proben

    6-fache Verbesserung der Genauigkeit und visuellen Korrelation bei Proben mit einem Reflexionsgrad von weniger als 20 %. Ermöglicht eine zuverlässige Messung dunkler, komplexer und visuell empfindlicher Materialien mit geringem Reflexionsgrad und subtilen visuellen Unterschieden.
  3. Präzision für sichtbar fluoreszierende Proben

    Gewährleisten Sie eine genaue Messung Ihrer schwer zu messenden retroreflektierenden und optisch aufgehellten Materialien mit echter D65-Quellenbeleuchtung und kontrollierter UV-Kalibrierung.
  1. Simplified Operator Experience

    New & Improved Color Software: Essentials 2.0 delivers lab-grade data in a clear, touch-optimized interface that supports confident, fast decisions.
  2. Smart User Interface with Touchscreen Display

    Durable and Efficient: Touch-friendly design speeds up workflows while the industrial glass face resists damage in high-use spaces.
  3. Rugged, Reliable Performance

    Spill-Proof Case: Sealed housing designed for the demands of real-world lab and production environments.
  1. Trusted Accuracy for Quality Teams

    0°/45° Circumferential Optical Geometry: Matches how the human eye views color, delivering results that reflect true appearance.
  2. Simultaneous Color & Gloss Measurement

    Color + 60° Gloss in One Step: Capture both values in a single read, streamlining reporting and simplifying your QA process.
  1. Advanced Data Export and Communication

    Flexible Connectivity: Ethernet and USB ports for exporting data and printing. HDMI and additional USB for accessories like monitor, keyboard, and mouse.
  2. Screen Recording Versatility and Built-in Camera for Sample Viewing

    Visual Accuracy: Confirms sample placement and lets you capture and share readings for clear quality documentation.
Agera L2 instrument settings display screen
  1. Secure User Management System 

    Workflow Control: Operator and admin roles protect data integrity and support compliance.
  2. Multi-Industry Versatility

    Built for Diverse Applications: Color, UV, and gloss control across plastics, safety apparel, neon clothing, DOT signage, retroreflectives, textiles, paper, packaging, and sports brands.
  3. Familiar Transition Path

    Agera Classic Mode: Available for teams accustomed to the original Agera experience

ProductSpecifications

Measurement

Measurement Principle: Dual-beam Reflectance Spectrophotometer / Glossmeter

Geometry Color: 0°/45°c (circumferential) ASTM E1164

Gloss: 60º

Measurement Method: Port up or Port forward

Read Time: < 3 sec.

Image Capture: High-resolution, D65 illuminated, 45°/0° image viewing, image capture and image recall

Port Plate Opening: Color: XL - 53.97 mm (2.125 in), L - 28.57 mm (1.125 in), M - 17.47 mm (0.688 in)

Area Measured:

  • Color: XLAV - 50.80 mm (2 in), LAV - 25.40 mm (1 in), MAV - 15.89 mm (0.625 in)
  • Gloss: 8 mm (5/16 in)

Illumination Range: 360 nm - 700 nm

Detection Range: 400 nm - 700 nm

Specular Component: Excluded

Spectral Resolution: < 3 nm

Effective Bandwidth: 10 nm equivalent triangular

Reporting Interval: 10 nm

Photometric Range: 0 to 150 %

UV Control: UV Included and UV Excluded with automated comparative data viewing and reporting. Factory calibrated with user option to calibrate to their specific fluorescent standard.

Light Source: Full spectrum, balanced LED array

LED Life: 5 years typical

Spectrophotometer: Sealed optics; 256-element diode array; high resolution concave holographic grating

Standards Conformance:

  • Color: CIE 15:2018, ASTM E1164, DIN 5033, Teil 7 and JIS Z 8722 Condition C;
  • Gloss 60°: ASTM D523, ASTM D2457, ISO 2813, ISO 7668, JIS Z 874

Performance

Inter-Instrument Agreement:

  • Color: ∆E 2000 < 0.20 CIE L*a*b* (Avg) on CCSII (CERAM) Tile Set
  • Gloss: 0 - 100 <= 0.5 GU

Repeatability:

  • Color: ∆E*< 0.03 CIE L*a*b* (Max) on white tile
  • Gloss: 0 - 100 GU: ≤0.1 GU

User Interface

Data Views: EZ View, Color Data Table, Color Plot, Spectral Data, Spectral Plot, Chromaticity Plot

Other Features: Pass/Fail Color Indication, time and date stamp, Auto-naming, auto-saving, Image Capture via high-resolution camera, average multiple measurements, time-based automatic measurements, data backup and recovery

USB Flash Drive Features: Data Export: Job Data, Sample Images, Screen Capture and Database

Illuminants: A, C, D50, D55, D65, D75, F02, F07, F11

Observers: 2° and 10°

Color Scales: CIE L*a*b*, Hunter Lab, CIE L*C*h, CIE Yxy, CIE XYZ

Color Difference Scales: ∆L*a*b*, ∆Lab, ∆L*C*h, ∆Yxy, ∆XYZ

Indices and Metrics: E313 Whiteness Index, Ganz Whiteness Index, E313 Tint, Ganz Tint, E313 Yellowness, D1925 Yellowness Index, Y Brightness, Z%, 457 nm Brightness, Baking Contrast Units, ASTM E1349, ISO 18314-3 Blackness (My, Mc, dM) and Greyness (Gy, Gc, dG)

Color Difference Indices: ∆E*, ∆E, ∆C*, ∆E CMC, ∆E 2000, , dC*, dH*, Strength at Max. Absorbance, Strength weighted, Metamerism, Grey Scale Color, Grey Scale Stain, Shade Number 555

Languages: Supports multiple languages—with the option to add more as needed

Data Storage: 8 GB (> 1 million data records with images)

Communications I/O

USB Connections: Connectivity to printer, keyboard, mouse- Front panel (1); Rear panel (2)

Ethernet RJ45: Print directly to standalone or network printers Stream data to LIMS and SPC systems

External Inputs: Remote Footswitch or similar closed contact switching device

Remote Access Support: Enabled via internet-based support tool

Physical / Electrical

Sensor Dimensions:

  • Height: 28 cm (11 in)
  • Width: 22 cm (8.75 in)
  • Depth: 31 cm (12.25 in)
  • Weight: 7.7 kg (17 lb)

Display: 7”Capacitive touch screen, high-resolution (1280 x 800)

Interface: 3 USB ports, HDMI Video Output, Foot switch Input, Ethernet connection, USB Service Port, Convenient physical measurement/action button

Power: Input: 100 to 240 VAC, 47 to 63 Hz to universal power supply @ 24 VDC (3.75A 90W)

Operating Environment: 10° to 40° C (50° to 104° F), 10 % to 90 % RH, noncondensing

Storage Environment: -20° to 65° C (-5° to 150° F), 10 % to 90 % RH, noncondensing

System Components:

  • Agera L2 sensor
  • XL - 53.97 mm (2.125 in), L - 28.57 mm (1.125 in), M - 17.47 mm (0.688 in) port plates
  • Certified Instrument Standard with NIST Certificate of Traceability 
  • Black Glass Standard used for both color and gloss standardization 
  • Diagnostic Check Standard 
  • 100V - 240V universal power supply
  • Agera L2 Quick Start Guide
  • Agera L2 User’s Guide (electronic)

Was ist in der Box?

Alles, was Sie brauchen, um in wenigen Minuten eine genaue Farbmessung zu erhalten!

Wesentliche Artikel

Zubehör

Trusted By The Best All Over The World

  • Kuraray logo
  • 3M logo

Master Your Color Quality with
Agera L2.

Schedule a Demo of the new Agera L2

Schedule Demo