Chlorophyll is an important quality indicator in edible oil refining. Its concentration helps manufacturers assess crude oil quality, evaluate refining performance and maintain consistent product appearance.

Suspended particles can scatter light and affect absorbance readings, making sample clarity an important consideration when measuring chlorophyll-related pigments.

In a single measurement, the HunterLab Vista® L2 spectrophotometer measures chlorophyll-related pigments, liquid color and haze to assess edible oil color and clarity.

Why is chlorophyll measured in edible oils?

Chlorophyll contributes to the green color found in many vegetable oils. Its presence provides information about the raw material and how effectively pigments have been reduced during refining.

Manufacturers use pigment measurements to evaluate incoming oils and assess how effectively refining reduces chlorophyll-related pigments.

Visual inspection can reveal noticeable differences in oil color, but it cannot quantify chlorophyll concentration. Spectrophotometric measurements provide numerical results that laboratories can use for quality grading and batch comparisons.

How is chlorophyll measured in edible oils?

AOCS Cc 13d-55 uses transmission absorbance at 630, 670 and 710 nm to determine the concentration of chlorophyll-related pigments, predominantly pheophytin a, in mg/kg (ppm). It applies to oils within the method's scope, such as refined and bleached oils before deodorization.

The calculation subtracts the average absorbance at 630 and 710 nm from the absorbance at 670 nm to correct for background absorbance.

Use a clear oil sample free of haze, moisture and particulates for this method. If the oil is visibly cloudy or the haze check flags a clarity issue, follow the applicable sample preparation procedure before measuring pigment concentration.

How to measure chlorophyll in edible oils with Vista L2

Oil residue in the sample cell, trapped air bubbles and inconsistent pathlengths can affect absorbance readings. HunterLab recommends the following practices when testing edible oils:

  1. Select the appropriate chlorophyll measurement method. Configure the instrument according to the required testing procedure.
  2. Use clean optical cells. Check for oil residue or contamination from previous samples before filling the cell.
  3. Maintain a consistent pathlength. Use the same optical pathlength when comparing measurements from different oil samples.
  4. Remove air bubbles. Inspect the filled cell before measurement, as bubbles can interfere with light transmission.
  5. Standardize the instrument regularly. Follow HunterLab's recommended standardization procedure.
  6. Measure representative production samples. Collect samples that reflect the oil being evaluated rather than relying on an unrepresentative portion of the batch.
Leer  Las 5 cosas que debe saber sobre la medición del color de los cerramientos de plástico opaco

Measure chlorophyll, color and haze with one instrument

The HunterLab Vista® L2 is a transmission spectrophotometer designed for transparent materials, including edible oils.

Along with the chlorophyll concentration metric, Vista L2 reports LOVIBOND® RYBN, AOCS RY, CIELAB and haze.

For laboratories that perform several tests on the same oil, these capabilities reduce the need to use separate instruments for routine color and clarity measurements.

Vista L2 also includes EasyMatch® Essentials L2 software directly on the instrument. Operators can create standards, measure samples, evaluate tolerances, review trends and generate reports using the onboard touchscreen. These routine functions require no external PC.

Manufacturers managing quality data across multiple instruments or facilities can use optional EasyMatch® Quality Central software to centralize results, standardize methods and review statistical process control (SPC) trends. The software also supports integration with data collection system, as well as continuity with legacy EasyMatch QC data.

How can chlorophyll measurements help monitor edible oil refining?

Measurements from comparable batches at the same refining stage can help manufacturers monitor pigment removal.

For example, if pigment levels in bleached oil begin rising above their usual range, the QC team can review the corresponding production records and refining conditions.

Chlorophyll data can indicate that further investigation is needed, but the measurement alone cannot establish which processing condition caused the variation.

Can chlorophyll be measured in canola, soybean and olive oil?

Transmission spectrophotometry can be used to evaluate chlorophyll-related pigments in edible oils. Choose a method based on both the oil type and its processing history. For example, virgin olive oil may require a method designed for cold-pressed oils.

Why is chlorophyll removed during vegetable oil refining?

Chlorophyll contributes to the green appearance of vegetable oils. Reducing its concentration helps manufacturers achieve the desired appearance of refined oil and meet established quality requirements.

Can a change in oil appearance indicate a refining problem?

A noticeable change in oil color or clarity may indicate a difference in the material or processing conditions. Laboratory measurements can help characterize that difference, while production records and other quality results provide the information needed to investigate its cause.

INFO  Más información